ESFR (Early Suppression Fast Response) Sprinkler

ESFR sprinklers has 3 difference compared to other sprinklers; Speed – ESFR sprinkler are twice faster to detect and active compared to other type sprinklers. Volume – While other sprinklers blow 25-60gpm water, ESFR sprinklers blow water up to 100gpm. Drop size – ESFR sprinkler heads blow bigger water drops compared to other sprinklers.

ESFR – K:14 (200) Pendent

  • Connection: ¾”npt
  • Assembly: Pendent (Hanging) Type
  • K-Factor: 14 (200)
  • Approval: FM, UL, ULC, LPCB, VdS
  • Temperature: 74°C, 96°C
  • Surface: Brass
  • Sin:VK500- ESFR(Early Suppression, Fast Response)
  • – Sensitive to temperature provided by fusible link.
  • – Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers gives the more water with more less pressure.
  • – If the users do correct pressure adjustments for ESFR Sprinklers, users don’t need any other sprinkler use for the between shelf.

Documents

FM UL
VIKING CATALOG

ESFR – K:14 (200) Upright

  • Connection: ¾”npt
  • Assembly: Upright
  • K-Factor: 14 (200)
  • Approvals: FM
  • Temperature: 74°C, 96°C
  • Surface: Brass
  • Sin: VK520- ESFR(Early Suppression, Fast Response)
  • – Sensitive to temperature provided by fusible link.
  • – Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers gives the more water with more less pressure.
  • – If the users do correct pressure adjustments for ESFR Sprinklers, users don’t need any other sprinkler use for the between shelf.
  • – Provided with unique upright design it’s the only solution where it’s not possible to use pendent sprinklers.

Documents

FM
VIKING CATALOG

ESFR – K:16.8 (242) Pendent

  • Connection: ¾”npt
  • Assembly: Pendent
  • K-Factor: 16.8 (242)
  • Approvals: FM, UL, ULC, LPCB, VdS
  • Temperature: 74°C, 96°C
  • Surface: Brass
  • Sin: VK503- ESFR(Early Suppression, Fast Response)
  • – Sensitive to temperature provided by fusible link.
  • – Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers gives the more water with more less pressure.
  • – If the users do correct pressure adjustments for ESFR Sprinklers, users don’t need any other sprinkler use for the between shelf.
  • – Requires lower pressure compared to ESFR K:14

Documents

FM UL
VIKING CATALOG

ESFR – K:22.4 (320) Pendent

  • Connection: 1”npt
  • Assembly: Pendent
  • K-Factor: 22.4 (320)
  • Approvals: FM, UL, ULC, LPCB, VdS
  • Temperature: 74°C, 96°C
  • Surface: Brass
  • Sin: VK506- ESFR(Early Suppression, Fast Response)
  • – Sensitive to temperature provided by fusible link.
  • –  Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers gives the more water with more less pressure.
  • – If the users do correct pressure adjustments for ESFR Sprinklers, users don’t need any other sprinkler use for the between shelf.
  • – Requires lower pressure compared to ESFR K:17

Documents

FM UL
VIKING CATALOG

ESFR – K:25 (363) Pendent

  • Connection: 1”npt
  • Assembly: Pendent
  • K-Factor: 25 (363)
  • Onaylar: FM, UL, ULC, LPCB, VdS
  • Temperature: 74°C, 96°C
  • Surface: Brass
  • Sin: VK510- ESFR(Early Suppression, Fast Response)
  • – Sensitive to temperature provided by fusible link.
  • – Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers gives the more water with more less pressure.
  • – If the users do correct pressure adjustments for ESFR Sprinklers, users don’t need any other sprinkler use for the between shelf.
  • – Requires lower pressure compared to ESFR K:22.4

Documents

FM UL
VIKING CATALOG

AYVAZ WAREHOUSE TYPE SPRINKLER

INQUIRY FORM

Please send us your request using our contact form; We will contact you immediately.