ELO (Large Drop) Sprinkler
ELO Upright Standard Response Sprinkler K:11.2 (160)
- Connection: ¾”npt
- Assembly: Upright
- K-Factor: 11.2 (160)
- Approvals: FM, UL, ULC
- Temperature: 68°C, 79°C, 93°C, 141°C
- Surface: Brass
- Sin: Temperature sensitive VK530 5mm Glass Bulb. – High Challenge Large Drop Sprinklers are designed to omit using sprinklers between shelves in warehouses with storage height 7.6 m and floor height is up to 9.1mm, within fires range of Group A plastics. – Distance between sprinkler’s deflector and the last pallette shouldn’t be lower than 914 mm.
Documents
ELO Upright Quick Response K:11.2 (160)
- Connection: ¾”npt
- Assembly: Upright
- K-Factor: 11.2 (160)
- Approvals: FM, UL, ULC
- Temperature: 68°C, 79°C, 93°C, 141°C
- Surface: Brass
- Sin: Temperature sensitive VK531 3mm Glass Bulb. – High Challenge Large Drop Sprinklers are designed to omit using sprinklers between shelves in warehouses with storage height 7.6 m and floor height is up to 9.1mm, within fires range of Group A plastics. – Distance between sprinkler’s deflector and the last pallette shouldn’t be lower than 914 mm.
Documents
ELO Pendent Standard Response Sprinkler K:11.2 (160)
- Connection: ¾”npt
- Assembly: Upright / Pendent
- K-Factor: 11.2 (160)
- Approval: FM, UL, ULC
- Temperature: 68°C, 79°C, 93°C, 141°C
- Surface: Brass, Chrome, White and Black
- Sin: Temperature sensitive VK536 5mm Glass Bulb. – Standart response sprinklers. – Extra wide orifice sprinklers are designed to use ın high concentration warehouses and workshops. – Lower pressure requirement means smaller pipe dimension, smaller pump capacity, that leads to a more economical solution. – Once used together with sprinkler protection cage and cover, it can be used as intermediate level sprinkler.
Documents
ELO Pendent Quick Response Sprinkler K:11.2 (160)
- Connection: ¾”npt
- Assembly: Upright
- K-Factor: 11.2 (160)
- Approval: FM, UL, ULC
- Temperature: 68°C, 79°C, 93°C, 141°C
- Surface: Brass
- Sin: Temperature sensitive VK377 3mm Glass Bulb. – Quick response sprinklers. – Extra wide orifice sprinklers are designed to use ın high concentration warehouses and workshops. – Lower pressure requirement means smaller pipe dimension, smaller pump capacity, that leads to a more economical solution. – Once used together with sprinkler protection cage and cover, it can be used as intermediate level sprinkler.
Documents